Ricoh R3111x Series Instrukcja Użytkownika Strona 20

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 31
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 19
R3114x
20
Voltage level Indicator Circuit (lighted when the power runs out)
(Nch Open Drain Output)
R3114xxx1A
Series
V
DD
GND
OUT
V
DD
Detector Threshold Adjustable Circuit 1
(Nch Open Drain Output)
R3114xxx1A
Series
GND
V
DD
V
up
R
up
OUT
Rb
V
DD
Ra
Adjustable Detector Threshold
=(VDET)×(Ra+Rb)/Rb
Hysteresis Voltage
=(VHYS)×(Ra+Rb)/Rb
1) To prevent oscillation, set Ra
<
=
1k, Rb
<
=
100.
2) If the value of Ra is set excessively large, voltage drop
may occur caused by the supply current of IC itself,
and detector threshold and hysteresis voltage may
vary.
3) If Vup and VDD are connected, the voltage dropdown
caused by R
up, may cause difference in the hysteresis
voltage.
Detector Threshold Adjustable Circuit 2
(Nch Open Drain Output)
R3114xxx1A
Series
GND
V
DD
V
up
R
up
OUT
Rb
V
DD
Ra
C
Adjustable Detector Threshold
=(VDET)×(Ra+Rb)/Rb
Hysteresis Voltage
=(VHYS)×(Ra+Rb)/Rb
1) To prevent oscillation, set Ra
<
=
100k, C
>
=
0.01μF.
2) If the value of Ra is set excessively large, voltage drop
may occur caused by the supply current of IC itself,
and detector threshold and hysteresis voltage may
vary.
3) If Vup and VDD are connected, the voltage dropdown
caused by R
up, may cause difference in the hysteresis
voltage.
4) If the value of Ra, Rb and C are set excessively large,
the delay of the start-up may become too long.