Installing Options
81
Attaching IEEE 1284 Interface Board Type
A
Before manipulating the 1284 interface board, touch something metal to dis-
charge static electricity. Static electricity thing damage the 1284 interface
board.
Do not subject the 1284 interface board to physical shocks.
A Check the package contains the following:
IEEE 1284 Interface Board Type A
B Turn off the power, and then unplug the power cable.
C Loosen the two screws and remove the cover of the 1284 interface board
installation unit.
The removed cover and two screws are not used when installing the 1284 in-
terface board.
Do not touch inside the controller board compartment. Doing so may cause
a machine malfunction or a burn.